Genie Garage Door Openers

GCL-GT

HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR

The GCL-GT is designed for standard lift sectional doors that have up to 60-cycle/hour duty requirement. Advanced features and robust mechanical design combine to provide a heavy-duty operator that sets a new standard for productivity.

GCL-GT Modifications and Options

Click here to view all options and modifications for all models.

MODIFICATIONS

09 - DUAL TROLLEY KIT - HEAVY-DUTY

Kit provides dual trolley installations with GCL-GT (ordered separately) on doors 20' wide and over. Dual trolley allows for distributed lifting of very large doors. This reduces the strain on the top section of the door. This kit works with 1/2, 3/4 and 1 HP GCL-GT operators.

 

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

 

OPTIONS

018 - COMMERCIAL PHOTOEYE SYSTEM

Commercial photoeye system in heavy-gauge sheet metal protected housing. Provides multiple mounting options with maximum adjustability. Designed to accommodate 1/2" flexible or rigid conduit, when required.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

019 - TIMER CLOSE MODULE

Timer to close expansion module. Provides for:

  • Timed Close - adjustable from 1 second to 5 minutes.
  • Pre-close Warning Output Contacts - adjustable from 2 to 10 seconds prior to close.
  • Auxiliary Open Input - provides additional open input that can be configured to start timer.
  • N-C Normally Closed Safety Input - Non-monitored N-C edge or photoeye input.
  • Monitored Edge Input - Provides contacts to connect 2-wire "DC" monitored edges.
  • Plug & Play - Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
  • Set-Up - LCD display is used to adjust settings and selection of inputs to start timer.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

020 - AUXILIARY OUTPUT MODULE

Auxiliary Output Module

  • Up Limit Output - Contacts activate when door reaches up limit. N-O and N-C contacts included. 2 sets of single-pole, double-throw (SPDT) contacts.
  • Down Limit Output - Contacts activate when door reaches down limit. N-O and N-C contacts included. 2 sets of single-pole, double-throw (SPDT) contacts.
  • ADA Output - Contacts configurable via LCD to activate when door is moving open, closed, or both open and closed. 1 set of single-pole, double-throw (SPDT) contacts.
  • Plug and Play - Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
  • Lamp Output - Contacts activate when door is set into movement and has a five-minute delay before turning off. 1 set of single-pole, double-throw (SPDT) contacts.
  • Set-Up - LCD display is used to adjust ADA output.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

 

ENVIRONMENTAL MODIFICATIONS

021 - TOTALLY ENCLOSED FAN-COOLED (TEFC) MOTOR

Replaces the standard open drip proof with a TEFC motor. Note that the 3 HP GCL-GH operators come standard with TEFC. This modification only changes the motor when needed per specification. TEFC models are not acceptable for damp or wet environments.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

022 - TOTALLY ENCLOSED NON-VENTILATED (TENV) MOTOR

Replaces the standard open drip proof with a TENV motor. This modification affects the motor only. TENV models are not acceptable for damp or wet environments.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

023 - 220V, 50HZ SINGLE PHASE

Modification allows the operator to be used with 220V, 1Ø, 50Hz power for international use. The standard motor is replaced by a motor rated for 50Hz use. This option is only available on 1/2, 1 and 3 HP models with brakes.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

024 - 220V, 50HZ THREE PHASE

Modification allows the operator to be used with 220V, 3Ø, 50Hz power for international use. The standard motor is replaced by a motor rated for 50Hz use. This option is only available on 1/2, 1 and 3 HP models with brakes.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

025 - 380-415V, 50HZ THREE PHASE

Modification allows the operator to be used with 380-415, 3Ø, 50Hz power for international use. The standard motor is replaced by a motor rated for 50Hz use. This option is only available on 1/2, 1, and 3 HP models with brakes.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

026 - NEMA 4/12 Watertight/Oiltight

Modification allows the operator to be used in damp environments. Provides protection against water spray. The unit is provided with a NEMA 4 Open/Close/Stop push-button standard. This option is only available on 1/2, and 1 HP models with brakes. Available with 50Hz models.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

027 - NEMA 4X Corrosion-Resistant

Modification allows the operator to be used in damp corrosive environments. The unit is provided with a NEMA 4x Open/Close/Stop push-button standard. This option is only available on 1/2, 3/4 and 1 HP Standard-Duty models with brakes, and 1/2, 1, and 3 HP Heavy-Duty models.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

028 - NEMA 7/9 HAZARDOUS AREA WALL-MOUNT

Coming soon

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH