Genie Garage Door Openers

GCL-H

STANDARD-DUTY HOIST OPERATOR

The GCL-H is designed for high or full-lift sectional and rolling doors that have a
30-cycle/hour or less duty requirement. Advanced features and robust mechanical design combine to provide a standard-duty operator that sets a new standard for productivity.

GCL-H Modifications and Options

Click here to view all options and modifications for all models.

MODIFICATIONS

02 - DC DISC BRAKE, STANDARD-DUTY HOIST OPERATORS

24V DC disc brake used on standard-duty hoist operators. This brake will provide up to 45 inch pounds of torque at motor speed. Brake is standard on 3/4 and 1 HP models. May be ordered from factory on the operator, or as a field installed kit.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

010 - CENTER MOUNT KIT - STANDARD-DUTY HOIST MODEL

This kit allows for a GCL-H operator to be center mounted and have the hoist extended to the side of the door. Center mounting is recommended on very large, over 20' wide, shaft-driven installations.

 

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

 

OPTIONS

018 - COMMERCIAL PHOTOEYE SYSTEM

Commercial photoeye system in heavy-gauge sheet metal protected housing. Provides multiple mounting options with maximum adjustability. Designed to accommodate 1/2" flexible or rigid conduit, when required.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

019 - TIMER CLOSE MODULE

Timer to close expansion module. Provides for:

  • Timed Close - adjustable from 1 second to 5 minutes.
  • Pre-close Warning Output Contacts - adjustable from 2 to 10 seconds prior to close.
  • Auxiliary Open Input - provides additional open input that can be configured to start timer.
  • N-C Normally Closed Safety Input - Non-monitored N-C edge or photoeye input.
  • Monitored Edge Input - Provides contacts to connect 2-wire "DC" monitored edges.
  • Plug & Play - Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
  • Set-Up - LCD display is used to adjust settings and selection of inputs to start timer.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

020 - AUXILIARY OUTPUT MODULE

Auxiliary Output Module

  • Up Limit Output - Contacts activate when door reaches up limit. N-O and N-C contacts included. Two sets of single-pole, double-throw (SPDT) contacts.
  • Down Limit Output - Contacts activate when door reaches down limit. N-O and N-C contacts included. Two sets of single-pole, double-throw (SPDT) contacts.
  • ADA Output - Contacts configurable via LCD to activate when door is moving open, closed, or both open and closed. One set of single-pole, double-throw (SPDT) contacts.
  • Plug and Play - Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
  • Lamp Output - Contacts activate when door is set into movement and has a five-minute delay before turning off. One set of single-pole, double-throw (SPDT) contacts.
  • Set-Up - LCD display is used to adjust ADA output.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

 

ENVIRONMENTAL MODIFICATIONS

021 - TOTALLY ENCLOSED FAN-COOLED (TEFC) MOTOR

Replaces the standard open drip proof with a TEFC motor. Note that the 3 HP GCL-GH operators come standard with TEFC. This modification only changes the motor when needed per specification. TEFC models are not acceptable for damp or wet environments.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

022 - TOTALLY ENCLOSED NON-VENTILATED (TENV) MOTOR

Replaces the standard open drip proof with a TENV motor. This modification affects the motor only. TENV models are not acceptable for damp or wet environments.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

023 - 220V, 50HZ SINGLE PHASE

Modification allows the operator to be used with 220V, 1Ø, 50Hz power for international use. The standard motor is replaced by a motor rated for 50Hz use. This option is only available on 1/2, 1 and 3 HP models with brakes.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

024 - 220V, 50HZ THREE PHASE

Modification allows the operator to be used with 220V, 3Ø, 50Hz power for international use. The standard motor is replaced by a motor rated for 50Hz use. This option is only available on 1/2, 1 and 3 HP models with brakes.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

025 - 380-415V, 50HZ THREE PHASE

Modification allows the operator to be used with 380-415, 3Ø, 50Hz power for international use. The standard motor is replaced by a motor rated for 50Hz use. This option is only available on 1/2, 1, and 3 HP models with brakes.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

026 - NEMA 4/12 WATERTIGHT/OIL-TIGHT

Modification allows the operator to be used in damp environments. Provides protection against water spray. The unit is provided with a NEMA 4 Open/Close/Stop push-button standard. This option is only available on 1/2, and 1 HP models with brakes. Available with 50Hz models.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

027 - NEMA 4X CORROSION-RESISTANT

Modification allows the operator to be used in damp corrosive environments. The unit is provided with a NEMA 4x Open/Close/Stop push-button standard. This option is only available on 1/2, 3/4 and 1 HP Standard-Duty models with brakes, and 1/2, 1, and 3 HP Heavy-Duty models.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH