Genie Garage Door Openers

GCL-H

STANDARD-DUTY HOIST OPERATOR

The GCL-H is designed for high or full-lift sectional and rolling doors that have a
30-cycle/hour or less duty requirement. Advanced features and robust mechanical design combine to provide a standard-duty operator that sets a new standard for productivity.

DOOR CHARTS

MAX DOOR SIZE (SQ FT) - SECTIONAL
Door Series Commercial Steel Insulated & Non-Insulated
216 216 Ins. 220 220 Ins. 2415 2415 Ins. 2411 2411 Ins.
Flush Ribbed
Model Max Door Wt. (lbs) 16GA. 16GA. Ins. 20GA. Steel 20GA. Ins. 24GA. 24GA. Ins. Nominal 24GA. Nominal 24GA. Ins.
1/2 HP 1120 256 220 370 256 440 340 320 320
3/4 HP 1370 330 256 440 310 530 400 320 320
1 HP 1620 380 280 500 370 570 410 320 320
MAX DOOR SIZE (SQ FT) - SECTIONAL
Door Series Thermospan® ThermoMark™ Aluminum
125 150 200 200-20 5150 5200 451 452
Insulated Insulated
Model Max Door Wt. (lbs) PU-FIP PU-FIP 1.38" PU-FIP 2" PU-FIP 2" 20GA. Ext. PU-FIP Raised Panel 1.38" PU-FIP Raised Panel 2" 1/8" Glass 1.38" 1/4" or 1/2" Glass 1.38"
1/2 HP 1120 256 360 400 300 400 380 360 240
3/4 HP 1370 256 450 450 370 460 440 400 330
1 HP 1620 256 480 480 420 500 480 400 400

 

MAX DOOR SIZE (SQ FT) - ROLLING
Door Series Steel Non-Insulated
Model Max Door Wt. (lbs) 16GA. 18GA. 20GA. 22GA. 24GA. 26GA.
1/2 HP 998 297 333 333 416 476 476
3/4 HP 1220 359 419 419 552 618 N/A
1 HP 1440 388 461 461 606 621 N/A
MAX DOOR SIZE (SQ FT) - ROLLING
Door Series Steel Insulated Counter Doors Grilles
Model Max Door Wt. (lbs) 18GA. 20GA. 22GA. Aluminum STL/SST Aluminum STL/SST
1/2 HP 998 238 238 274 126 126 350 240
3/4 HP 1220 276 276 309 126 126 450 310
1 HP 1440 297 296 382 126 126 610 450

Notes:
1. Max Door Weight and not the square footage, is the critical factor in selecting the proper operator.
2. Max Door Height 24'
3. For "Commercial Steel Insulated" category, various "backer" options are available. The chart above is based in all cases on the thickest backer available.
4. "PU-FIP" stands for "polyurethane, foamed-in-place." If no notation is present, insulation is "polystyrene laid-in-place."

AMPERAGE RATING - 60Hz
HP 115V 1Ø 208V 1Ø 230V 1Ø 208V 3Ø 230V 3Ø 460V 3Ø 575V 3Ø
1/2 10 5 5 3 3 3 2
3/4 11 6 6 3 4 3 2
1 14 7 7 4 4 3 2

Dimension Drawing

GCL-H schematic

 

Wiring Diagram

Click here to view the GCL-H Wiring Diagram