Genie Garage Door Openers

GCL-MJ

MEDIUM-DUTY JACKSHAFT OPERATOR

The GCL-MJ is designed for high or full-lift sectional and rolling doors that have a limited-duty cycle requirement. Advanced features and robust mechanical design combine to provide a medium-duty operator that is the new standard in the industry.

GCL-MJ Options

Click here to view all options and modifications for all models.

OPTIONS

013 - EMERGENCY EGRESS - STANDARD FLUSH MOUNT

Allows for emergency manual egress by pulling wall-mounted lever. Flush, wall-mount emergency egress enclosure includes a mechanical cable to couple into operator. Door must be balanced so that it is able to open at least half way when released.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

014 - EMERGENCY EGRESS - ADA-COMPLIANT

Allows for ADA-compliant emergency manual egress by pulling wall-mounted lever. Flush wall mount emergency egress enclosure includes a mechanical cable to couple into operator. Door must be balanced so that it is able to open at least half way when released.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

018 - COMMERCIAL PHOTOEYE SYSTEM

Commercial photoeye system in heavy-gauge sheet metal protected housing. Provides multiple mounting options with maximum adjustability. Designed to accommodate 1/2" flexible or rigid conduit, when required.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

019 - TIMER CLOSE MODULE

Timer to close expansion module. Provides for:

  • Timed Close - adjustable from 1 second to 5 minutes.
  • Pre-close Warning Output Contacts - adjustable from 2 to 10 seconds prior to close.
  • Auxiliary Open Input - provides additional open input that can be configured to start timer.
  • N-C Normally Closed Safety Input - Non-monitored N-C edge or photoeye input.
  • Monitored Edge Input - Provides contacts to connect 2-wire "DC" monitored edges.
  • Plug & Play - Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
  • Set-Up - LCD display is used to adjust settings and selection of inputs to start timer.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH

020 - AUXILIARY OUTPUT MODULE

Auxiliary Output Module

  • Up Limit Output - Contacts activate when door reaches up limit. N-O and N-C contacts included. Two sets of single-pole, double-throw (SPDT) contacts.
  • Down Limit Output - Contacts activate when door reaches down limit. N-O and N-C contacts included. Two sets of single-pole, double-throw (SPDT) contacts.
  • ADA Output - Contacts configurable via LCD to activate when door is moving open, closed, or both open and closed. One set of single-pole, double-throw (SPDT) contacts.
  • Plug and Play - Plugs directly into control board expansion port, and can daisy chain with additional expansion modules.
  • Lamp Output - Contacts activate when door is set into movement and has a five-minute delay before turning off. One set of single-pole, double-throw (SPDT) contacts.
  • Set-Up - LCD display is used to adjust ADA output.

Works with models GCL-GCX GCL-MT GCL-T GCL-GT GCL-MJ GCL-J GCL-MH GCL-H GCL-GH